BJMTQ - KWIK MARINE REMOVER, MR-956

Product Identification

Product ID:KWIK MARINE REMOVER, MR-956
MSDS Date:05/07/1987
FSC:8010
NIIN:00N012044
MSDS Number: BJMTQ

Responsible Party
W M BARR & COMPANY, KLEEN-STRIP DIV
2105 CHANNEL AVENUE
MEMPHIS, TN 38101
US

Emergency Phone: 901-775-0100

Info Phone: 901-775-0100

Cage: FO265

Contractor
W.M. BARR & COMPANY/KLEAN-STRI, DIVISION OF
1879 MEMPHIS, TN 38101 US

Telephone: 901-775-0100

Cage: 91522

Ingredients

METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: < 90%

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PARAFFIN WAX

CAS: 8002-74-2

RTECS: RV0350000

Fraction By Weight: < 05%

OSHA PEL 2 MG/M3 (FUME)

ACGIH TLV: 2 MG/M3 (FUME); 9192


ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: < 05%

OSHA PEL 400 PPM/500 STEL

ACGIH TLV: 400 PPM/500STEL;9192


METHYL ALCOHOL (METHANOL) (SARA III)

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: < 10%

OSHA PEL S,200PPM/250STEL

ACGIH TLV: S,200PPM/250STEL; 93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


USE;DO NOT USE IN THE GEN VICIN OF ARC

RTECS: 9999999ZZ


RADIATION MAY CAUSE THE FORMATION OF HCL &/OR PHOSGENE .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:MAY CAUSE IRRIT OF RESP
TRACT,HEADACHE,DIZZ & STUPOR.MAY INCREASE CARBOXYHEMOGLOBIN LEVELS.
SEVERE OVEREXP MAY CAUSE UNCON.MAY BE FATAL/CAUSE
BLNDNESS.INGEST:MAY CAUSE INCREASE IN CARBOXYH EMOGLOBIN LEVELS.MAY
CAUSE NAUSEA,VOMIT& ABDOMINAL PAIN.MAY BE FATAL/CAUSE BLNDNESS.(SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:NTP - 2, IARC - 2B.
Effects of Overexposure:HLTH HAZ:SKIN:HARMFUL IF ABSORBED THROUGH
SKIN.MAY CAUSE IRRIT.EYE CNTCT: MAY CAUSE WATERING OF EYES &
IRRIT.MAY CAUSE CONJUNCT OF EYES.LONG TERM EFTS:MAY CAUSE SKIN
IRRIT/DERM ON PRLNGD/RPTD CNTCT. M AY CAUSE VISUAL
IMPAIRMENT/BLNDNESS. CHLOROCARBON/CHLOROFLUOROCARBON (CFC) MATLS
HAVE(SEE SUPP DATA)
Medical Cond Aggravated by Exposure:NONE RECOGNIZED.

First Aid

First Aid:INHAL: IF BREATHING DFCLT REMOVE TO AIR FREE OF VAPORS.
ADMINISTER OXYGEN OR ARTF RESP UNTIL MED ASSISTANCE CAN BE
RENDERED.INGEST:DO NOT INDUCE VOMITING. GET MD, POISON CONTROL
CENTER OR HOSPITAL EME RGENCY ROOM IMMEDIATELY. SKIN: WASH WITH
SOAP AND LARGE QUANTITIES OF WATER AND GET MD IF IRRIT PERSISTS.
EYE:FLUSH WITH LARGE QUANTITIES OF WATER FOR AT LEAST 15 MIN.IF
IRRIT PERSISTS, GET MD.

Fire Fighting

Flash Point:NO FLASH TO BP
Lower Limits:6 %
Extinguishing Media:NOT APPLICABLE (MFR).USE EXTINGUISHING MEDIA
SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:NOT APPLICABLE (MFR).WEAR NIOSH/MSHA APPROVED
PRESSURE DEMAND SCBA AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT APPLICABLE (MFR). THERMAL
DECOMPOSITION PRODUCTS MAY INCLUDE HCL AND PHOSGENE .

Accidental Release

Spill Release Procedures:FLUSH LARGE SPILLS OF MATL INTO SUITABLE
RETAINING AREA OR CNTNRS W/LARGE QTYS OF H*2O.SMALL SPILLS CAN BE
ABSORBED BY APPROP INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE NEAR FLAMES OR AT
ELEVATED TEMPS.
Other Precautions:READ CAREFULLY ALL CAUTNS & DIRECTIONS ON PROD LABEL
BEFORE USE.SINCE EMPTY CNTNR RETAINS RESIDUE,FOLLOW ALL LABEL
WARNINGS EVEN AFTER CNTNR IS EMPTY.DISPOSE OF EMPTY CNTNR ACCORDING
TO LOCAL REGULATI ONS.NO SMOKING IN AREA OF(SEE INGRED #5)

Exposure Controls

Respiratory Protection:FOR OSHA CTL WORK PLACE,USE ONLY W/ADEQ VENT
UNDER ENGINEERED AIR CTL SYS DESIGNED TO PROVIDE MAX APPROP TLV.FOR
OCCASN USE WHERE ENGINEERED AIR CONTROL IS NOT FEASIBLE,USE
NIOSH/MSHA APPRVD RESP.FOR OCCASN CONSUMER USE W/ ADEQ VENT.
Ventilation:ADEQUATE VENT MUST BE PROVIDED.SEE RESPIRATORY PROTECTION.
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:CHEM WORKERS GOGGLES,FACESHLD OPT
Other Protective Equipment:VARYING APPLICATION METHODS CAN DICTATE USE
OF ADDITIONAL PROT SAFETY EQUIP SUCH AS IMPERMEABLE APRONS, ETC.
Work Hygienic Practices:WASH THORO AFTER USE & BEFORE
EATING,DRINKING,SMOKING/USING WASHROOM.BEFORE REUSE,CLEAN ANY
CONTAM CLTHG/PROT EQUIP.
Supplemental Safety and Health
EFTS OF OVEREXP:PRDCD SENSIT OF THE MYOCARDIUM TO EPINEPHRINE IN
LABORATORY ANIMALS & COULD HAVE A SIMILAR EFFECT IN HUMANS.
ADRENOMIMETICS (I.E.,EPINEPHRINE) MAY BE CONTRA-INDICATED EXCEPT
FOR LIFE-S USTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED
TO CHLOROCARBONS OR CFCS .

Chemical Properties

HCC:T4
Boiling Pt:B.P. Text:104F,40C
Vapor Pres:SEE INGRED
Vapor Density:> AIR
Spec Gravity:1.213
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:98.0

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY PRODUCE
HYDROGEN CHLORIDE AND SMALL QUANTITIES OF PHOSGENE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.